Effects of flow obstacles on pool boiling critical heat flux of a downward-facing metal heater
详细信息    查看全文
文摘

Pool boiling critical heat flux in a downward-facing heater decreases with an increase in the obstacle size.

The dry region behind obstacles stagnates due to the delayed edge separation.

The effect of obstacle shape suddenly intensified at a blockage ratio of 0.51.

Two edge separation of right-angled obstacle delays collapse of the dry region behind obstacles.

Curved-boundaries of obstacles are beneficial in delaying critical heat flux triggers.