Pool boiling critical heat flux in a downward-facing heater decreases with an increase in the obstacle size.
The dry region behind obstacles stagnates due to the delayed edge separation.
The effect of obstacle shape suddenly intensified at a blockage ratio of 0.51.
Two edge separation of right-angled obstacle delays collapse of the dry region behind obstacles.
Curved-boundaries of obstacles are beneficial in delaying critical heat flux triggers.