The application of IMRT is expected to improve treatment tolerability.
The real benefit on osteoradionecrosis risk reduction should not be clearly drawn.
Mandible should be contoured as whole organ, with alveolar bone, excluding teeth.
Dmax <70 Gy, V50 = 62 and V60 = 20 are dose constraints suggestions to reduce ORN.