Effect of denture cleansers on physical properties of heat-polymerized acrylic resin
详细信息    查看全文
文摘

Purpose

This study aimed to measure the color change, surface roughness and flexural strength of heat-polymerized acrylic resin after its immersion in denture cleansers, simulating a 180-day use.

Methods

Thirty disk-shaped (15 mm × 4 mm) and 30 rectangular samples (65 mm × 10 mm × 3.3 mm) were prepared from heat-polymerized acrylic resin and immersed in Corega Tabs, Bony Plus, and distilled water. Color measurements (ΔE) were determined by a portable colorimeter. A surface analyzer was used to measure the roughness before and after immersion (ΔRa). The flexural strength (S) was measured using a 3-point bending test. The ΔE values were submitted to statistical analysis by the Kruskal–Wallis test, followed by Dunn's Multiple Comparisons test. The ΔRa and S values were submitted to statistical analysis by ANOVA, followed by a Student–Newman–Keuls test (α = .05).

Results

The color changes were significantly higher for the Corega Tabs than for the control group. The mean ΔE values quantified by the National Bureau of Standards (NBS) were classified as Trace (0.0–0.5). The Bony Plus group had significantly higher surface roughness than the other groups. Corega Tabs and Bony Plus groups presented lower flexural strength than the control group.

Conclusions

Although the color changes after the immersion in denture cleansers were clinically insignificant, the Corega Tabs group showed higher color differences. The Bony Plus group showed significantly increased surface roughness. Both effervescent tablets Corega Tabs and Bony Plus significantly diminished the flexural strength of the acrylic resin.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700