Potential benefits of using non coplanar field and intensity modulated radiation therapy to preserve the heart in irradiation of lung tumors in the middle and lower lobes
详细信息    查看全文
文摘

Purpose

Investigate whether the use of non coplanar fields and intensity modulated radiation therapy (IMRT) reduces the dose to the heart, in irradiation of middle and lower lung tumors.

Materials and methods

Four plans are compared on 10 CT scans: (1) a reference plan, corresponding to coplanar plan of 3D conformal radiotherapy (3DCRT); (2) a 3DCRTnoncopl plan, differing from reference plan by the change of one field in non coplanar fields; (3) an IMRTcopl plan optimized on the same coplanar plan as reference plan; and (4) an IMRTnoncopl plan optimized on the same non coplanar beams as 3DCRTnoncopl plan. The equivalent uniform dose (EUD) for PTV was 74 Gy in 37 fractions.

Results

In all plans, the 95 % isodose surface covers at least 99 % of the PTV with very similar conformity index values. A significant reduction in EUD, V30, V40 and V50 is observed for heart when either non coplanar fields or IMRT is used. IMRT also reduces the lung NTCP, V5, V13, V20 and V30 values and esophagus NTCP.

Conclusion

Both the use of non coplanar fields and IMRT dramatically reduces the dose received by the heart. The largest benefit is seen when the two techniques are combined.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700