Preconcentration of some metal ions with lanthanum-8-hydroxyquinoline co-precipitation system
详细信息    查看全文
文摘
A method of separation and preconcentration of cadmium, copper, nickel, lead and zinc at trace level using 8-hydroxyquinoline as a chelating agent and lanthanum(III) as a carrier element is proposed. The heavy metals were determined after preconcentration by inductively coupled plasma optical emission spectrometry (ICP-OES). The results were compared with those obtained using flame atomic absorption spectrometry (F-AAS). The influence of several parameters such as pH, amount of lanthanum(III) as a carrier element, amount of 8-hydroxyquinoline, duration of co-precipitation was examined. Moreover, effects of inorganic matrix on recovery of the determined elements were studied. The detection limits (DL) for ICP-OES were 0.31, 2.9, 1.4, 3.2 and 1.2 渭g L鈭? for Cd, Cu, Ni, Pb and Zn, respectively, whereas for F-AAS DL were 0.63, 1.1, 3.2, 2.7 and 0.74 渭g L鈭?. The recovery of the method for the determined elements was better than 94% with relative standard deviation between 0.63% and 2.9%. The preconcentration factor was 60. The proposed method was successfully applied for determination of Cd, Cu, Ni, Pb, and Zn in plant materials. Accuracy of the proposed method was verified using certified reference material (NCS ZC85006 Tomato).

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700