Electrochemical oxidation of EG was carried out using boron doped diamond anode.
The degradation of EG was mainly attributed to direct anodic oxidation.
The best performance of EG degradation was recorded using Na2SO4 and 0.077 A/cm2.
Under the best conditions, 89.6 ± 0.2% of COD was removed after 120 min of treatment.