Quantitative Assessment of Retinal Nerve Fiber Layer Defect Depth Using Spectral-Domain Optical Coherence Tomography
详细信息    查看全文
文摘
To assess quantitatively the depth of retinal nerve fiber layer (RNFL) defects using a Cirrus high-definition (HD) optical coherence tomography (OCT)–derived RNFL thickness deviation map.

absSec_2">Design

abspara0015">Prospective, cross-sectional study.

absSec_3">Participants

abspara0020">Three-hundred fifteen eyes with localized and diffuse RNFL defects of 315 glaucoma patients and 217 eyes of 217 healthy subjects.

absSec_4">Methods

abspara0025">For the glaucoma subjects, the severity of the RNFL defect was graded on red-free fundus photographs by 2 observers using a standardized protocol with a 3-level grading system. The RNFL defect depth on the RNFL thickness deviation map was expressed as an RNFL defect depth percentage index (RDPI): 100×(1–[summation of thicknesses of RNFL defects {red or yellow superpixels}/summation of RNFL thicknesses of upper 95th percentile range of age-matched healthy subjects in areas corresponding to RNFL defects]).

absSec_5">Main Outcome Measures

abspara0030">Retinal nerve fiber layer defect depth percentage index, average and segmental (4 quadrants and 12 clock-hour sectors) circumpapillary RNFL (cpRNFL) thicknesses according to the RNFL defect severity, and the area under the receiver operating characteristic curves (AUROCs) for various OCT parameters.

absSec_6">Results

abspara0035">The RDPIs increased with the increasing severity of the RNFL defect in both the superior and inferior hemifields (P <0.05, 1-way analysis of variance test with Bonferroni correction). The AUROCs of the RDPIs (0.969 and 0.975 in the superior and inferior hemifields, respectively) were larger than those of all of the cpRNFL thicknesses in discriminating the mild from the moderate RNFL defects (P <0.05). Meanwhile, in discriminating the moderate from the severe RNFL defects, the AUROCs of the RDPIs (0.961 and 0.891 in the superior and inferior hemifields, respectively) were larger than those of the cpRNFL thicknesses in all areas except the inferior quadrant and the 6-, 7-, and 11-o'clock sectors (P <0.05).

absSec_7">Conclusions

abspara0040">The RDPI, a new parameter using a Cirrus HD OCT-derived RNFL thickness deviation map, can be a useful adjunct tool for objective quantification of RNFL defect depth. This parameter has an advantage over cpRNFL thickness in discriminating between mild and moderate RNFL defects, not in discriminating between moderate and severe defects.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700