Regeneration procedure of IE resins saturated after the treatment of OMW.
Study of effect of regenerant concentration and type, temperature and flow rate.
Minor flow rate provided the highest possible regeneration for all IE resins.
Above 96% were noted upon the lowest temperature examined (298 K).
Regeneration of the used IE resins with a minimum amount of residual pollutant ions.