TEE has been routinely used as an adjunct to angiography during TA-TAVI procedures, but very few data exist on the use of TEE as the primary imaging technique guiding TA-TAVI.
One hundred consecutive high-risk patients (mean age 79 ¡À 9 years, mean logistic EuroSCORE: 25.8 ¡À 17.6 % ) who underwent TA-TAVI in our center were included. The Edwards valve was used in all cases, and all procedures were performed in an operating room without hybrid facilities. The TA-TAVI was primarily guided by angiography in the first 25 patients (A-TAVI group) and by TEE in the last 75 patients (TEE-TAVI group). Procedural, 30-day, and follow-up results were evaluated.
No differences were observed between groups at baseline except for a higher (p = 0.001) prevalence of moderate or severe mitral regurgitation in the TEE-TAVI group. The procedure was successful in 97.3 % and 100 % of the patients in the TEE-TAVI and A-TAVI groups, respectively (p = 1.0), and a lower contrast volume was used in the TEE-TAVI group (12 [5 to 20] ml vs. 40 [20 to 50] ml, p < 0.0001). There were no differences between groups in the occurrence of valve malposition needing a second valve (TEE-TAVI: 5.3 % ; A-TAVI: 4 % ; p = 1.0) or valve embolization (TEE-TAVI: 1.3 % ; A-TAVI: 4 % ; p = 0.44). The results regarding post-procedural valve hemodynamic status and aortic regurgitation were similar between groups. The survival rates at 30-day and 1-year follow-up were 87 % and 75 % in the TEE-group and 88 % and 84 % in the A-TAVI group, respectively (log-rank = 0.49).
TEE-TAVI was associated with similar acute and midterm results as A-TAVI and significantly reduced contrast media use during the procedures. These results suggest the feasibility and safety of performing TA-TAVI procedures in an operating room without hybrid facilities, but larger studies are needed to confirm these findings.