Experiments were conducted in isolated mouse hearts (0.040 kg, n = 8), a Langendorff heart preparation is used to obtain two variables of the contractile response contraction force and heart rate. The contractile response due to an electrical stimulation perturbed with Gaussian noise was recorded.
The results show that the intensity of noise induced in the electrical stimuli has an effect on the electrical stimulation-contractile response coupling. With 10% noise induced, the bandwidth where the synchronization effect is presented was increased from (7–11 Hz) to (6–12 Hz), and the irregular dynamic threshold was changed to 13 Hz.
We find that the noise increases the synchronization bandwidth in the electrical stimulation-contractile response coupling. We have experimentally demonstrated the stochastic resonance in isolated mouse heart.