10 m-class long-distance loop heat pipe was developed based on calculation model.
Several tests were conducted under horizontal and anti-gravity conditions.
The gravity effect on the heat transport efficiency was evaluated.
Easier generation of vapor blanket as the increase of gravity effect was indicated.
It revealed the possibility for use of loop heat pipe in the terrestrial field.