Burnup measurement of fuel elements comprising the new equilibrium LEU silicide core of RSG GAS.
The burnup measurement method is based on a linear relationship between reactivity and burnup.
Burnup verification was conducted using an in-house, in-core fuel management code BATAN-FUEL.
A good agreement between the measured and calculated burnup was confirmed.
The new fuel management strategy was confirmed and validated.