Interfractional Variations in Patient Setup and Anatomic Change Assessed by Daily Computed Tomography
详细信息    查看全文
文摘
Purpose: To analyze the interfractional variations in patient setup and anatomic changes at seven anatomic sites observed in image-guided radiotherapy.

Methods and Materials: A total of 152 patients treated at seven anatomic sites using a Hi-Art helical tomotherapy system were analyzed. Daily tomotherapy megavoltage computed tomography images acquired before each treatment were fused to the planning kilovoltage computed tomography images to determine the daily setup errors and organ motions and deformations. The setup errors were corrected before treatment and were used, along with the organ motions, to determine the clinical target volume/planning target volume margins. The organ motions and deformations for 3 representative patient cases (pancreas, uterus, and soft-tissue sarcoma) and for 14 kidneys of 7 patients are presented.

Results: Interfractional setup errors in the skull, brain, and head and neck are significantly smaller than those in the chest, abdomen, pelvis, and extremities. These site-specific relationships are statistically significant. The margins required to account for these setup errors range from 3 to 8 mm for the seven sites. The margin to account for both setup errors and organ motions for kidney is 16 mm. Substantial interfractional anatomic changes were observed. For example, the pancreas moved up to ±20 mm and volumes of the uterus and sarcoma varied ≤30 % and 100 % , respectively.

Conclusion: The interfractional variations in patient setup and in shapes, sizes, and positions of both targets and normal structures are site specific and may be used to determine the site-specific margins. The data presented in this work dealing with seven anatomic sites may be useful in developing adaptive radiotherapy.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700