Experimental Evaluation of the Developmental Mechanism Underlying Fractures at the Adjacent Segment
详细信息    查看全文
文摘
Compression fractures at adjacent mobile segments have been reported as adjacent segment disease under trauma in several studies. In this study, the occurrence of fractures at the adjacent segment was evaluated experimentally under trauma.

Methods

Static testing of different fixation systems was performed to show their biomechanical performances. The ovine vertebrae fixed with rigid, dynamic, and semirigid systems were used as test samples. The stiffness values of the systems were obtained by testing the vertebrectomy models under compression bending, lateral bending, and torsion tests. In addition, their effects on the adjacent segments were experimentally evaluated within a drop mechanism. A free-fall drop mechanism was designed and manufactured. Next, 3.5-kg, 5-kg, and 7-kg weights were released from 1 m above the test samples to generate compression fractures. The occurrence of compression fractures was observed with the use of radiograph of test samples, which were obtained before and after the drop test.

Results

Dynamic and semirigid systems have advantages compared with rigid systems as the result of their lower stiffness values. Radiographs showed that epiphysis fractures occurred at fixed and adjacent mobile segments, which were fixed with semirigid fixation. In addition, dynamic fixation well preserved the fixed and adjacent mobile segments under trauma.

Conclusions

The dynamic system with a polyetheretherketone rod can better preserve both adjacent and fixed segments. However, because of the cantilever beam effect, the semirigid system exhibits a great disadvantage.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700