An improved procedure for the purification of a bacterial lipoprotein is presented.
The new procedure shortens the purification from 24 h to 4 h.
Detergent screening revealed that spiralin is mostly insoluble in Sarkosyl and Triton X-100.
Milligram quantities of highly pure spiralin can be obtained.
The procedure is non-denaturing.