Analysis of risk classification for massive transfusion in severe trauma using the gray zone approach
详细信息    查看全文
文摘
The Traumatic Bleeding Severity Score (TBSS) was developed to predict the need for massive transfusion (MT). The aim of this study is evaluation of clinical thresholds for activation of a MT protocol using the gray zone approach based on TBSS.

Methods

This is a single-center retrospective study of trauma patients, admitted from 2010 to 2013. The TBSS on admission was calculated, and the accuracy of predicting MT was analyzed using area under the receiver operating characteristic curve. Risk classification for MT was made using sensitivity/specificity. The gray zone (indeterminate risk) was defined from a sensitivity of 95% to a specificity of 95%, patients were separated into MT and non-MT groups, and their clinical characteristics were compared.

Results

A total of 264 patients were enrolled, with an area under the TBSS curve of 0.967 (95% confidence interval, 0.94-0.99). A TBSS of 10 points or less resulted in a sensitivity of 96.5% with 146 patients in this group, and 3.4% (5/146) of them received MT. A TBSS of 17 points or higher had a specificity of 97.8%, which included 72 patients, and 94.4% (68/72) of them received MT. Forty-six patients had a TBSS from 11 to 16 points (gray zone), and 26.1% (12/46) of them received MT. Comparing the MT group (12/46) and non-MT group (34/46), coagulopathy and extravasation on computed tomographic scan were more prevalent in the MT group.

Conclusion

The TBSS is highly accurate in predicting the need for MT, and a risk classification for needing MT was created based on TBSS.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700