Favorable Results of a Short, Tapered, Highly Porous, Proximally Coated Cementless Femoral Stem at a Minimum 4-Year Follow-Up
详细信息    查看全文
文摘
Shorter femoral stems have been increasingly used in total hip arthroplasty. However, there are few clinical studies evaluating the outcomes of these stems and comparing them to their regular-sized counterparts.

Methods

Our study provides radiologic and functional outcomes at 5-year mean follow-up of 131 cementless Tri-Lock Bone Preservation Stems, a short tapered stem with a proximal porous coating.

Results

Stem-related complications were low with one revision for stem aseptic loosening. Kaplan-Meier analysis estimated 99.2% stem survival rate at 5 years, comparable to conventional length Tri-Lock stems (99.8% at 8.9 years).

Conclusion

This study demonstrates that the Tri-Lock Bone Preservation Stem can provide successful outcomes at 5-year follow-up. Further studies are required to determine the long-term outcome of these implants in patients with poor bone stock.