A scanning Hall probe microscope (SHPM) equipped with three GaAs films was developed.
The magnetic field intensity decreases during crack growth.
Polarization of the magnetic field occurs ahead of the fatigue cracks.
The polarization moves while the crack grows.
The magnetic fields move as the plastic area expands.