Numerical Simulation for Effect of Inlet Cooling Rate on Fluid Flow and Temperature Distribution in Tundish
详细信息    查看全文
文摘
The fluid flow in tundish is a non-isothermal process and the temperature variation of stream from teeming ladle dominates the fluid flow and thermal distribution in tundish. A numerical model was established to investigate the effect of inlet cooling rate on fluid flow and temperature distribution in tundish based on a FTSC (Flexible Thin Slab Casting) tundish. The inlet cooling rate varies from 0.5 to 0.25 ¡ãC/min. Under the present calculation conditions, the following conclusions were made. When the stream temperature from teeming ladle drops seriously (for inlet cooling rate of 0.5 ¡ãC/min), there is a ¡°backward flow¡± at the coming end of casting. The horizontal flow along the free surface turns to flow along the bottom of tundish. The bottom flow shortens the fluid flow route in tundish and deteriorates the removal effect of nonmetallic inclusions from molten steel. Nevertheless, when the inlet cooling rate decreases to 0.25 ¡ãC/min, the horizontal flow is sustained during the whole casting period. The present research provides theoretical directions for temperature control in teeming ladle and continuous casting tundish during production of advanced steels.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700