Fully predictive heat transfer coefficient modeling of an axial flux permanent magnet synchronous machine with geometrical parameters of the magnets
详细信息    查看全文
文摘

Convective heat transfer in an axial flux permanent magnet machine is investigated.

The reference temperature is calculated through a minimization method.

The proposed correlations are independent of the surface temperatures.

The stator heat transfer in the gap reaches a maximum at a certain gap size ratio.

The magnets act as a centrifugal fan, causing efficient air gap cooling.