Villermaux¨CDushman protocol for experimental characterization of micromixers
详细信息    查看全文
文摘
The iodide/iodate chemical test reaction (named Villermaux¨CDushman method) initially proposed to characterize micromixing in conventional stirred tank reactors has become an extensive method to characterize continuous micromixers. Several protocols have been proposed and adapted to very efficient devices, but misunderstanding makes the use of this chemical test somewhat difficult which can lead to erroneous results. Furthermore, many papers only present the segregation index which is very dependent of the concentration set when mixing time, a concentration-free feature, should be preferred to compare micromixers. This paper presents the detailed protocol of the iodide/iodate test method, with different concentration sets and a general protocol to determine mixing times in micromixers.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700