A total of 610 middle-aged (50-67 years) subjects from a population-based sample (MONICA Augsburg, Germany) were characterized with respect to LA area and volume from the apical two-chamber (2C) and four-chamber (4C) views in addition to M-mode echocardiography. ANP and BNP concentrations were determined by radioimmunoassay.
A significant correlation to ANP and BNP was present with all measures on LA size. The univariate correlation was lowest with M-mode diameter (r = 0.11 with ANP; r = 0.09 with BNP, both P < .03), whereas 2C volume displayed the closest correlation (r = 0.20 with ANP and r = 0.28 with BNP, both P < .001) and even slightly exceeded 2C area, 4C volume, and 4C area. 2C volume further displaced LV systolic function, mass index, and heart rate as statistically significant predictors of ANP (P < .001) and BNP (P < .001) on adjusted regression analysis, whereas M-mode diameter was displaced as a significant predictor of ANP and BNP (P = not significant).
The current population-based echocardiographic study allows new insight into the value of different measures of LA size. The closer association between natriuretic peptide concentrations and parameters derived from planimetry and volumetry suggests a superiority of these parameters LA diameter. LA volumetry should be included in routine echocardiography for optimized assessment of LA size.