Radiation level analysis for the port cell of the ITER electron cyclotron-heating upper launcher
详细信息    查看全文
文摘

First detailed neutronic modelling of the ECHUL port cell with ECHUL equipment (including beam lines with diamond windows, the beam lines mounting box, conduit boxes and rails).

Three different bioshield port plug configurations and two different neutron source configurations are investigated.

Radiation Levels are calculated in the port cell, focusing on the position of the diamond window.

The dose rate in the port cell is below the limit for maintenance in the port cell.

The radiation level at the diamond window is very low and should not influence its performance.