Analytical error model for swing arm profilometry.
Error sources include axial, radial, tilt motions of rotary tables and misalignment.
Surface reconstruction by stitching multiple intersectant traces.
Error motions of the part rotary table are optimally recognized and then removed.
Error motions of sub-milliradian scale are tolerant with surface reconstruction.