Conventional ISCFPD frameworks were fabricated by casting gold alloys; however, with the recent advancement of CAD/CAM technology, titanium (Ti) or yttria tetragonal zirconia polycrystal (Y-TZP) frameworks have become more common. In contrast, the main fabrication method for Ti or Co-Cr frameworks of removable dental prostheses has shifted from the conventional casting method to CAD/CAM fabrication. Ce-TZP/A, which was chosen as the framework material this time, shows higher strength and greater toughness than Y-TZP. However, since it has a low light-transmitting property and exhibits an opaque white color, the range of its application in fixed prostheses, particularly in the esthetic area, is limited.
We described a case in which Ce-TZP/A was applied to the frameworks of a mandibular ISCFPD and a maxillary complete denture. No particularly notable biological or prosthetic complications were observed in the mandibular ISCFPD or the maxillary complete denture, and a high level of patient satisfaction was achieved. Medium- and long-term observations with a greater number of cases are essential to obtain information concerning various phenomena related to this procedure.