Emissions of PCBs from 13 caulk samples were tested in a micro-chamber system.
Nineteen light ballasts from five manufacturers were tested in 53-L chambers.
Emission rates of PCB congener from caulk and light ballasts were determined.
Several factors that may have affected the emission rates were evaluated.
New data and methods for ranking the primary sources of PCBs were provided.