Reducing natural organic matter and disinfection by-product precursors by alternating oxic and anoxic conditions during engineered short residence time riverbank filtration: A laboratory-scale column study
详细信息    查看全文
文摘

Engineered river bank filtration was tested with 6 days retention time.

Organic matter and disinfection by-product precursor removal ranged from 40 to 90%.

Alternating oxic and anoxic conditions increased overall performance.

High dissolved oxygen availability favours C-DBP precursor removal.

Prolonged anoxic phases favour N-DBP precursor removal.