Material compatibility is an important factor to consider during the development of new lubricants and sealing materials. Static immersion tests provide a first idea about the compatibility between elastomeric materials and lubricants. For the same material combination, significant deviations among the test results of different laboratories have been reported. In order to identify the relevant factors affecting the results, a systematic investigation was carried out. Reproducibility tests show that the estimation of the compatibility is compromised due to the deviations that appear for the change of the mechanical properties of the considered reference elastomers. The influences of the closure of the test apparatus and the volume ratio, as well as the development of the aging process, were investigated. The results showed that, in order to differentiate between elastomer-lubricant material combinations, standard test durations of approximately 1008 h are preferred. Volume ratios of 64 and 80 and small variations of the vessel closure did not lead to significant deviations of the results. In contrast, tests with open and closed vessels showed significant deviations for the hardness and mechanical properties of the elastomeric materials.