Low-temperature aeration to control Indianmeal moth, Plodia interpunctella (Hübner), in stored grain in twelve locations in the United States: a simulation study
详细信息    查看全文
文摘
Aeration management strategies were developed to control cold-acclimated and diapausing Indianmeal moth, Plodia interpunctella (Hübner), larvae in grain bins during winter in north- and east-central regions of the US. The application in this study focuses on corn because it is the dominant crop in these regions, but we believe that the analyses can be applied to other grains as well. Contour maps for hours below −10 °C for the months of December, January, and February were developed to help effective planning and management of aeration to control overwintering stored-grain insects. Two cumulative lethality index (CLI) models were developed to estimate mortality of laboratory-reared (diapausing without cold-acclimation) and field-collected (cold-acclimated, and diapausing with cold-acclimation) P. interpunctella larvae under changing temperature conditions. The CLI models were used for evaluating aeration management strategies. Simulation studies were conducted using 30 years of weather data for 12 locations in north- and east-central regions of the US to evaluate different aeration management strategies for controlling P. interpunctella larvae. For each strategy, temperatures of headspace air and grain in the top meter of the grain mass were simulated using an existing model for the period of December–February. The tested management strategies included no aeration, continuous aeration, and intermittent aeration by controlling fan operation. During aeration, air was pulled from the headspace downward through the grain with an airflow rate of 0.11 m3/min-t (0.1 cfm/bu). Simulation results indicated that a fan control strategy that turned the aeration fan on when the grain temperature at 0.4-m depth was greater than the headspace-air temperature was the best strategy for managing P. interpunctella larvae in all tested locations. For this strategy, the CLI model indicated that 100 % mortality of P. interpunctella larvae could be achieved at a grain depth of 0.4 m from the top grain surface in all locations. For this strategy, the aeration fan operated about 10 % of the time from December to February. The average cost of electrical energy required for aeration fan operation with this strategy for all locations was 1.3 ¢/t (0.033 ¢/bu) based on an electrical energy cost of 7 ¢/kWh.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700