Evaluation of rapid maxillary expansion through acoustic emission technique and relative soft tissue attenuation
详细信息    查看全文
文摘
Acoustic emission (AE) is a non-destructive test to detect energy release. This technique was applied during rapid maxillary expansion (RME) to evaluate the reaction of the craniofacial skeleton.Materials and methodsA swine model was analysed. Soft tissues were removed from two heads, while other two were preserved intact. A palatal expander (PE) was positioned and AE sensors were placed on the intermaxillary, fronto-nasal, and maxillo-lacrimal sutures. The PE was activated and AE recorded during RME. Differences between parameters were analysed with Mann-Whitney U test and Kruskal-Wallis test, and correlations with Spearman-Rho test (significance p<0.05).ResultsPE activations were accompanied by clusters of AE hits. In the presence of soft tissues, amplitudes were generally lower (p<0.001) and durations were higher (p<0.001). No differences were found in the respective energy values. Differences were found in the AE (p<0.05) among the four channels, with AE characterised by higher values in proximity of the maxillo-lacrimal sutures. High-energy hits were represented by burst-type waves, and low-energy ones by continuous-type.ConclusionsAlthough soft tissues create possible attenuation of the signal, AE can be detected during RME with sensors on the skin. AE provided further information of energy release, on top of the mechanical parameters. Source location was one of the main limitations.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700