Skin dose in breast brachytherapy: Defining a robust metric
详细信息    查看全文
文摘
To define a simple, robust, and relevant metric for measuring skin dose in breast brachytherapy.

Methods and Materials

Postoperative treatment plans (Day 0) for 15 permanent breast seed implant (PBSI) and 10 multicatheter high-dose-rate (MC-HDR) brachytherapy patients were included. Retrospectively, three skin structures were contoured: 2 mm external from the body; and subsurface layers 2 mm and 4 mm thick. Maximum point dose (Dmax), doses to small volumes (e.g., D0.2cc), and the volumes receiving a percentage of the prescription dose (V%, e.g., V66) were calculated. D0.2cc was investigated as a surrogate to the dose given to 1 cm2 of skin (D1cm2). Pearson product–moment correlation (R2) was computed between metrics.

Results

Observed trends were consistent across brachytherapy technique. V% did not correlate well with any other metrics: median (range) R2, 0.63 (0.43, 0.77) and 0.69 (0.3, 0.89) for PBSI and MC-HDR, respectively. Dmax was inconsistently correlated across contours and not well correlated with doses to small volumes: median (range) R2, 0.85 (0.76, 0.93) and 0.88 (0.83, 0.93) for PBSI and MC-HDR, respectively. In contrast, doses to small volumes were consistently well correlated, even across skin layers: D0.1cc vs. D0.2cc median (range) R2, 0.98 (0.97, 0.99) and 0.97 (0.94, 0.99) for PBSI and MC-HDR, respectively.

Conclusions

Doses to small volumes are robust measures of breast skin dose and given skin's strong area effect, D0.2cc for a 2 mm thick skin layer, a simple surrogate of D1cm2, is recommended for recording skin dose in any breast brachytherapy. Dmax is not robust and should be avoided.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700