Polymerization efficiency and flexural strength of low-stress restorative composites
详细信息    查看全文
文摘
To assess depth of cure (DOC), degree of conversion (DC), and flexural strength (FS) of several resin composites with low-stress behavior.

Methods

SonicFill (Kerr), SureFil® SDR™ (Dentsply), everX Posterior (GC), Kalore (GC), and Filtek Silorane (3M ESPE) were tested. DOC was measured with the Acetone Shake test. DC was assessed with Fourier Transform Infra-Red spectroscopy on top and at the bottom of 4 mm-thick disk-shaped specimens. Bottom to top ratios of DC percentages were calculated. FS was evaluated with the Three-Point Bending test. DOC, DC, and FS data were statistically analyzed.

Results

SureFil® SDR™ and everX Posterior achieved significantly greater DOC than Kalore and Filtek Silorane. Also, SonicFill had significantly greater DOC than Filtek Silorane. Mean top DCs ranged between 71.46% and 52.44%. Kalore and everX Posterior had significantly lower top DCs than the other materials. Mean DC values at 4 mm ranged largely from 57.95% to 6.82%. Kalore and Filtek Silorane had the lowest values of bottom DC and the difference was statistically significant. EverX Posterior and SonicFill recorded significantly higher FSs than the other materials.

Significance

SureFil® SDR™ and everX Posterior exhibited DOC over 4 mm, the maximum thickness recommended for bulk placement, while SonicFill recorded DOC values very close to the 4 mm threshold. SonicFill achieved the highest DC at the irradiated surface, as well as at 4 mm depth. SureFil® SDR™ demonstrated similarly uniform curing through the bulk increment. All the tested composites complied with the requirements of FS established by ISO 4049/2009.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700