Chilli hotness determination based on optical capsaicin biosensor using stacked immobilisation technique
详细信息    查看全文
文摘
The fabrication of an optical biosensor based on stacked immobilisation of 3-methyl-2-benzothiazolinone hydrazone (MBTH) in sol-gel/butyl acrylate hybrid film and horseradish peroxidase (HRP) in chitosan film for capsaicin detection was studied. The optimum volume ratio of sol-gel to butyl acrylate was 1:0.5 (v/v). Peroxidase was immobilised in chitosan film deposited on top of the hybrid sol-gel/butyl acrylate film containing MBTH. The reaction between capsaicin and MBTH in the presence of HRP and hydrogen peroxide as oxidative agent was studied. The finding indicated that HRP catalysed the oxidative coupling reaction between MBTH and capsaicin thus producing red-coloured azo-dye compounds that could be observed at the wavelength of 505 nm. The colour intensity of the product was found to increase in proportion to the capsaicin concentration after 20-30 s of exposure. The linearity of the biosensor towards capsaicin was in the concentration range of 0.2-4.0 mM with detection limit of 0.17 mM. Relative standard deviation (RSD) values of reproducibility were 5.57-6.33%. The developed biosensor correlated well with the standard method, HPLC for the determination of capsaicin concentration in real samples.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700