Experimental investigations of the minimum ignition energy and the minimum ignition temperature of inert and combustible dust cloud mixtures
详细信息    查看全文
文摘

Ignition sensitivity of a highly flammable dust decreases upon addition of inert dust.

Minimum ignition temperature of a highly flammable dust increases when inert concentration increase.

Minimum ignition energy of a highly flammable dust increases when inert concentration increase.

The permissible range for the inert mixture to minimize the ignition risk lies between 60 to 80%.