The waste heat recovery system is modeled by three-dimensional thermal resistance.
This is a time-saving and efficient method to estimate power generation from TEGs.
Relations between power generation and varied factors can be rapidly revealed.
TEGs positions and uniformity of velocity profile should be considered together.
Power generation is more sensitive to either internal or external flow velocity.