Thorium and particle data measured using settling velocity sediment traps were used in this study.
A “two-layer” model was built to describe thorium particle interactions.
Maximum likelihood method was applied to estimate particle thorium reaction rate constants.
Source and sink terms for 234Th and 230Th were clearly defined.