Parametric study of small low-temperature organic Rankine cycle system is conducted. R245fa is used as working fluid, and scroll expander as a power generation device. System performance increases and then decreases with increasing refrigerant charge. System performance increases with increasing pressure ratio and mass flow rate. System power and efficiency decrease with increasing heat sink temperature.