A 3D model was developed to study nail penetration induced thermal runaway.
Effects of flow rate, thermal abuse reactions, and nail dimensions were examined.
Minichannel cooling at cell level cannot cease thermal runaway in a single cell.
Minichannel cooling can prevent thermal runaway propagation between cells.