A strain gage technique for the determination of mixed mode stress intensity factors of orthotropic materials
详细信息    查看全文
文摘
A theoretical frame work is developed for strain gage based determination of mixed mode (KI/KII) stress intensity factors (SIFs) in slant edge cracked plate (SECP) made of orthotropic materials. Using three parameter strain series around the crack tip and appropriate stress functions, the present formulation shows that mixed mode SIFs in orthotropic materials could be determined using only four strain gages. A finite element based methodology is developed to determine the upper bound on the radial location (rmax) of strain gages ensuring accurate determination of SIFs. Proposed technique is applied to numerical simulation of [02/90]2S and [0/±45/90]S glass-epoxy SECP laminates to demonstrate accurate determination of mixed mode SIFs by placing the gages within rmax. Results from the present work provide clear guidelines in terms of number of strain gages and their suggested locations for accurate determination of mixed mode SIFs in orthotropic materials.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700