Continuous compaction control (CCC) allows for real-time monitoring of compaction. Machine drive power and compactometer value data compared against in situ tests. Point-by-point comparisons yielded low correlation; average data sets fared better. Including the effects of moisture content yielded better regression models. Different interpolation methods for CCC data yielded similar regression results.