Effect of asymmetric variation of operating parameters on EED cell for HI concentration in I-S cycle for hydrogen production
详细信息    查看全文
文摘
EED process for HI concentration was studied for the effect of individual operating parameters such as I2/HI ratio, concentration of , temperature and pressure. Studies were conducted in an asymmetric system where the effects of operating parameters were varied for anolyte and the catholyte separately. Open circuit voltage (OCV) was found to be a contributor toward the net potential drop across the EED cell. Ohmic resistance was found to decrease with increase in I2/HI ratio in catholyte and was found to increase with increase in I2/HI ratio in anolyte. Increase in decreased the resistance for anolyte section whereas caused an increase in resistance for catholyte section. Increase in temperature reduced the voltage drop and the resistance across the EED cell. A non-zero differential pressure between the two compartments of the cell increased the resistance across the cell without affecting the OCV value. Electrode potential studies at the graphite electrodes showed an increase in the electro potential with increase in the iodine concentration and decrease with the increase in the HI concentration. Energy required for concentrating acid increased linearly with current density favoring operation at low current densities. Energy consumed in overcoming OCV contributed substantial fraction of the total energy consumed in EED process at lower current densities.