Retrieval of a stripped abutment screw: A clinical report
详细信息    查看全文
文摘
Mechanical complications, such as loosening or damaging of the prosthetic components of an osseointegrated implant, may occur. Stripping of the implant abutment screw head can be a serious problem which can render an implant unusable. This report describes a clinical situation involving a patient who presented with a fractured screw-retained interim crown. Upon further examination, it was determined that the abutment screw head was stripped. There was limited access and visibility in this situation since the implant was a bone-level implant. The procedure used for the removal of the stripped abutment screw head is described in detail in this clinical report.