DEHP emission rates from PVC sheets were measured using passive gas flux samplers.
Surface concentrations were determined using the data and a transient model.
Surface concentrations matched published values (most determined using chambers).
This method provides surface SVOC concentrations quickly and simply.
The surface concentrations correlated well with the DEHP contents of the PVC sheets.