Local and overall wind pressure and force coefficients for solar panels
详细信息    查看全文
文摘
This paper reports on an experimental study carried out to better understand the wind pressure distribution on stand-alone panel surfaces and panels attached to flat building roofs. A complex model capable to incorporate solar panels at different locations and various inclinations was constructed at a 1:200 geometric scale. Three model panels equipped with pressure taps on both surfaces (36 in total) for point and area-averaged pressure measurements were used. Pressure and force coefficients were computed for every pressure tap and for all the panels. Different configurations were tested under similar conditions in order to examine the effect of various parameters on the experimental results. A minimal gap occurred between the solar panels and the roof of the model. The study found that the net values of pressure coefficients corresponding to different configurations are affected by the panel inclination for the critical 135掳 wind direction, for which panels on the back location undergo higher suctions in comparison to those in the front. The effect of building height on the solar collector total load is minimal, whereas corner panels are subjected to higher net loads for critical azimuths. Simplified net pressure coefficients for the design of solar panels are provided.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700