In this prospective study, all patients older than 18 years who were admitted for orthopedic surgery and who had a CTA performed for PE were eligible. These patients underwent an ETCO2 measurement. Patients were determined to have PE if they had a positive PE-protocol CT.
Between May 2014 and April 2015, 121 patients met the inclusion criteria for the study. Of these patients, 84 had a negative CTA examination, 25 had a positive examination, and 12 had a nondiagnostic examination. We found a statistically significant difference (P = .03) when comparing the average ETCO2 values for the positive and negative CTA groups. An ETCO2 cutoff value of 43 mm Hg was 100% sensitive with a negative predictive value of 100% for absence of PE on CTA.
This study demonstrates a significant difference in ETCO2 measurements between postoperative orthopedic patients with and without CTA-detected PE. A cutoff value of >43 mm Hg may be useful in excluding patients from undergoing CTA.