Direct analysis of microstructures of alkyl phenol resin using atmospheric pressure chemical ionization-mass spectrometry
详细信息    查看全文
文摘
Alkyl phenol resin was directly analyzed using atmospheric pressure chemical ionization-mass spectrometry (APCI-MS). Analysis was performed in both positive and negative ion modes, and product ions were only observed in the negative ion mode. By interpreting the m/z values of [M - H]? ions, the degree of polymerization, the types of linkages and the types of terminals could be determined. The monomer, dimer, trimer, tetramer and pentamer species were observed. The methylene and dimethylene ether linkages were distinguished. For the terminal types, the methylol, o-methylene quinone, hydrogen, and aldehyde were distinguished. Influence of the types of solvents and eluents on the ionization efficiencies were investigated using acetone, chloroform and tetrahydrofuran. Recommendable solvent and eluent system for the analysis of resin using APCI-MS was acetone.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700