Forty patients (American Society of Anesthesiologists grades I and II) scheduled for elective gastrointestinal surgery were enrolled in our study. After anesthesia induction, 6% hydroxyethyl starch solution was administered to patients as an intravenous (IV) fluid. The IVC diameters were measured with ultrasonography. SVV and stroke volume index (SVI) were obtained from the Vigileo monitor. All data were collected both before and after fluid challenge.
Forty patients underwent IVC sonographic measurements and SVV calculation. After fluid challenge, mean arterial pressure, central venous pressure, SVI, and IVC diameters increased significantly, whereas SVV decreased markedly. The correlation coefficient between the increase in SVI and the baseline of IVC variation after an IV fluid was 0.710, and receiver operating characteristic (ROC) curve was 0.85. The correlation coefficient between the increase in SVI and the baseline of SVV was 0.803 with an ROC curve of 0.93. Central venous pressure had no significant correlation with SVI.
Our data show that IVC variation and SVV proved to be reliable predictors of fluid responsiveness in patients undergoing anesthesia for surgery with mechanical ventilation.