Surrogate H/D Detection Strategy for Protein Conformational Analysis Using MS/MS Data
详细信息    查看全文
  • 作者:Andrew J. Percy ; Gordon W. Slysz ; David C. Schriemer
  • 刊名:Analytical Chemistry
  • 出版年:2009
  • 出版时间:October 1, 2009
  • 年:2009
  • 卷:81
  • 期:19
  • 页码:7900-7907
  • 全文大小:304K
  • 年卷期:v.81,no.19(October 1, 2009)
  • ISSN:1520-6882
文摘
Amide hydrogen/deuterium exchange (H/DX) measurements by mass spectrometry provide a powerful tool for probing the structure and dynamics of proteins. In order to extend such measurements to complex multiprotein systems, new methods for delivering higher sensitivity and sequence coverage are required. In this study, we investigated the utility of tandem mass spectrometry (MS/MS) for providing an alternative to the conventional MS mode of operation applied to bottom-up H/DX experiments. Specifically, we aimed to determine whether differential deuteration measurements of collisionally induced dissociation (CID)-generated product ions can serve as effective surrogates for their corresponding intact peptide, thus providing an additional dimension for analysis. Replicate deuterium measurements of calmodulin (in its apo and holo forms) were obtained from peptic digests in both the MS and MS/MS domains and studied as a function of % deuteration, fragment ion selection, and contaminant level. We show that successful acquisition of MS/MS data for deuterated peptides requires controlled expansion of the isotopic envelope by limiting the range of deuterium label applied in the exchange-in reaction (≤50%) and that automation of ion selection via data-dependent acquisition is ultimately dependent upon peak detection algorithms. Upon full transmission of the isotopic envelope, fragment data demonstrate that all ions, with the exception of neutral loss fragment ions, return deuteration ratios reflecting the apo/holo transition that are in general agreement with values obtained from the corresponding precursor ions. The agreement is limited primarily by the ion statistics for each fragment, as the base peak in the MS/MS spectra provided the best correlation regardless of its m/z. We highlight that the freedom to select the base peak as a surrogate for the precursor ion derives from extensive H/D scrambling inducible under conventional CID conditions. When spectral interference prohibits conventional H/DX-MS measurements, we further show that the surrogate approach recovers accurate and precise per-peptide deuteration levels. Thus, a generalized strategy is presented in which CID-based automated H/DX-MS/MS acquisition can be used to extend measurements to complex protein systems, exceeding the peptide capacity of conventional H/DX-MS alone.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700