Use of Portable Analytical Methods to Determine the Stoichiometry of Reaction for Hexahydrotriazine-Based Hydrogen Sulfide Scavenger Operations
详细信息    查看全文
  • 作者:Grahame N. Taylor ; Ron Matherly
  • 刊名:Analytical Chemistry
  • 出版年:2014
  • 出版时间:May 20, 2014
  • 年:2014
  • 卷:86
  • 期:10
  • 页码:4879-4882
  • 全文大小:259K
  • 年卷期:v.86,no.10(May 20, 2014)
  • ISSN:1520-6882
文摘
During the reaction between 1,3,5-tris(2-hydroxyethyl)hexahydro-s-triazine and hydrogen sulphide, the principle by-product is the organic sulphide 5-(2-hydroxyethyl)dithiazine. It can be determined by a novel, portable, field-capable ion mobility spectrometry method described herein and enables the 鈥渄egree spent鈥?to be determined. Dependant upon the level of carbon dioxide in the produced gas, a mixture of ethanolaminium bicarbonate and ethanolamine bisulphide is also produced. Using a field capable spectrophotometric method the level of inorganic sulphide can be determined, thus allowing the ethanolaminium bisulphide concentration to be calculated. Provided the fluid is only partially spent, and there is some unreacted 1,3,5-tris(2-hydroxyethyl)hexahydro-s-triazine remaining; the only source of inorganic sulphide is the amine salt. From a knowledge of the original fluid concentration, the combination of these two methods allows the effective stoichiometry, or observed molar reaction proportions between 1,3,5-tris(2-hydroxyethyl)hexahydro-s-triazine and hydrogen sulphide, to be measured for a specific field location.